Further Configuration. Remember to configure your light matrix in the » Matrix Generator or » Patch Editor. Data is automatically sent to all corresponding sACN devices in the network.

X according to the Streaming ACN specifications. X IP address range! Make sure to select the correct network adapter that will be used for Streaming ACN! It is not necessary to change any of these networks settings. Please set the exact number of devices you are using. If the count is higher, this creates unnecessary network traffic.

From this point onwards it will be used on your PC. Interfaces can detect this unique ID and can be configured to receive data from this particular device. Please note that the ACN interface must support this feature. This name is send via network as well. Therefore, interfaces may be able to retrieve this name and can be configured to receive data from this source. Valid values range from 0 to , which is the highest priority. Using Unicast the data packets are sent directly to the device instead of being broadcast across the entire subnet.

Multicast is a method to send data across a network where a sender, typically a PC, broadcasts the data to all devices connected to the network subnet and the information about the channels are sent to all controllers connected to the network and every other device on the network. Multicast is a point to multipoint broadcast where the controllers need to listen to and only respond to information they are configured to use.

Your PC sequencing software or streaming tool sends multicast packets with an address of As an example, the address for universe '1' would be This is why using multicast addressing can be simpler to configure since this address is always the same for any device using that universe. Depending on the device and the number of universes of data sent it can swamp the device and possibly end up causing a loss of data. Note however that this is not an issue for most networks until you get into the dozens of universes so it's not an issue for most users.

With Multicast you must also have a unique IP address for each controller so that you can access its webpage that allows configuration. The data is received on multicast IP address not on the configuration IP address. In order for this to work with a Pixel Controller or E1. You can chose any universe number from and assign it to a block of channels in your sequencing software.

While a Universe can contain up to channels, it does not have to, and can be any number between channels. If you are using the E68x series E, E, E, E of pixel controllers, you can only use channels maximum per universe. If you are using more then one universe of channels in your sequencing software, then you must setup each of the multiple universes in your sequencing software and also map them to the appropriate channels in your sequence.

You only need to install one output plugin in the sequencing software and add all of the universe mapings into that one output plugin. Once you have setup your sequencing software E1. Since E1. It is possible to use a single ethernet cable to connect a E1. To connect directly, it is necessary to put the PC and the E1. It is also possible to connect an E1. This configuration also allows multiple E1.

It is also possible to use multiple PCs to send data to the controllers over the network. Interfaces can detect this unique ID and can be configured to receive data from this particular device.

Please note that the ACN interface must support this feature. In the next step, please open the "Device Manager" in the menu "Preferences".

Or press "F4" on your keyboard. A new window will open. In the our example, 10 devices were created. Next, please select one device in the list and click "Configure Device In addition, you can perform a double-click on this device. A new dialog will open. This name is send via network as well. Therefore, interfaces may be able to retrieve this name and can be configured to receive data from this source. You can manually adjust the settings. Valid values range from 0 to , which is the highest priority.

One gets a priority of The second PC gets a priority of If the first PC fails and only if it malfunctions, data will be automatically received from PC 2. After that, to build, open the. PRO file in the root directory and build with Qt Creator. Skip to content. Star Branches Tags. Could not load branches.